Nuvair O2 Quickstick Analyzer

Nuvair O2 Quickstick Analyzer

$340.00
Skip to product information
Nuvair O2 Quickstick Analyzer

Nuvair O2 Quickstick Analyzer

$340.00

O2 Quickstick Analyzer

The Nuvair O2 Quickstick is the first truly diver-friendly handheld oxygen analyzer designed for fast, reliable gas verification in the field. Rugged, compact, and remarkably affordable, it gives divers the confidence of verifying their own nitrox or oxygen mixes without relying on shared equipment.

Built with a sealed, water-resistant housing and anodized marine-grade aluminum body, the O2 Quickstick is nearly indestructible and perfectly suited for boats, fill stations, and travel kits. No hoses, adapters, or cables are required—just turn it on, calibrate, and analyze.

Whether you're analyzing nitrox at the dock or confirming oxygen content above water, the O2 Quickstick delivers professional-grade performance in a pocket-sized device.

Includes clear protective sleeve.


Key Features

  • Fast response thermally compensated sensor

  • Fully sealed, water-resistant housing

  • No hoses, adapters, or cables required

  • Simple calibration process

  • User-replaceable battery and oxygen sensor

  • Magnetic waterproof on/off switch to preserve battery life

  • Anodized marine-grade aluminum body

  • Compact, pocket-size design


Specifications

  • Flow Rate: 0.5–2 L/min

  • Resolution: 0.1%

  • Accuracy: ±1% of full scale at constant temperature and pressure (0–1 atm) when calibrated with 100% oxygen

  • Sensor Type: Electrochemical

  • Expected Sensor Life: 36 months in air at 25°C / 77°F and 50% RH

  • Range: 0–100% oxygen

  • Response Time: <6 seconds to 90% of final value

  • Operating Temperature: 32–104°F (0–40°C)

  • Operating Humidity: 0–99% RH (non-condensing)

  • Storage Temperature: 32–122°F (0–50°C)

  • Power: 9V alkaline battery

  • Dimensions: 9 in (L) × 1.5 in (W) (23 × 4 cm)

  • Weight: 21.1 oz (.34 kg)

Warranty:

  • 0–12 Months: Free replacement

  • 13–18 Months: 50% off replacement

  • 19–24 Months: 25% off replacement


Important Safety Note

The dome-shaped end cover is designed to restrict gas flow to the sensor. Improper tank valve operation or incorrect analyzer use can cause sensor damage or false readings. Inaccurate gas analysis can lead to serious personal injury or death. Always consult the O2 Quickstick User Manual before use.


Replacement Parts

  • Oxygen Sensor 9510

  • (A) Sensor Connector Cable

  • (B) CDB (Circular Distribution Board)

  • (C) Voltage Regulator Connector Cable

  • (D) 9-Volt Battery Connector Cable

  • (E) 7-Wire Connector Cable

  • (F) Potentiometer & Connector Cable