{"product_id":"regulator-2nd-stage-full-service-complete-rebuild","title":"Regulator 2nd Stage Full Service (Complete Rebuild) Labor","description":"\u003cp data-end=\"998\" data-start=\"627\"\u003eThe \u003cstrong data-end=\"657\" data-start=\"631\"\u003e2nd Stage Full Service\u003c\/strong\u003e at \u003ca href=\"https:\/\/www.scubarepair.com\" title=\"scubarepair.com\"\u003e\u003cstrong data-end=\"680\" data-start=\"661\"\u003eScubaRepair.com\u003c\/strong\u003e\u003c\/a\u003e is a complete professional rebuild of your scuba regulator’s second stage to restore smooth breathing performance, proper cracking pressure, and reliable operation. This service is recommended for regulators due for scheduled overhaul, experiencing free flow, breathing resistance, or general performance degradation.\u003c\/p\u003e\n\u003cp data-end=\"1382\" data-start=\"1000\"\u003eEach second stage is \u003cstrong data-end=\"1043\" data-start=\"1021\"\u003efully disassembled\u003c\/strong\u003e, cleaned, inspected, and rebuilt using \u003cstrong data-end=\"1121\" data-start=\"1083\"\u003eOEM manufacturer service kits only\u003c\/strong\u003e. No aftermarket components are used. All seals are replaced with \u003cstrong data-end=\"1203\" data-start=\"1187\"\u003eOMPF O-rings\u003c\/strong\u003e, and lubrication is performed exclusively with \u003cstrong data-end=\"1267\" data-start=\"1251\"\u003eChristo-Lube\u003c\/strong\u003e to ensure material compatibility with air, Nitrox, and oxygen-enriched service within manufacturer specifications.\u003c\/p\u003e\n\u003ch3 data-end=\"1405\" data-start=\"1384\"\u003eWhat’s Included\u003c\/h3\u003e\n\u003cul data-end=\"1832\" data-start=\"1406\"\u003e\n\u003cli data-end=\"1451\" data-start=\"1406\"\u003e\n\u003cp data-end=\"1451\" data-start=\"1408\"\u003eComplete \u003cstrong data-end=\"1449\" data-start=\"1417\"\u003edisassembly of the 2nd stage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1504\" data-start=\"1452\"\u003e\n\u003cp data-end=\"1504\" data-start=\"1454\"\u003eUltrasonic and mechanical cleaning of components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1568\" data-start=\"1505\"\u003e\n\u003cp data-end=\"1568\" data-start=\"1507\"\u003eInspection of housing, lever, orifice, and valve components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1636\" data-start=\"1569\"\u003e\n\u003cp data-end=\"1636\" data-start=\"1571\"\u003eReplacement of all serviceable parts using \u003cstrong data-end=\"1634\" data-start=\"1614\"\u003eOEM service kits\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1678\" data-start=\"1637\"\u003e\n\u003cp data-end=\"1678\" data-start=\"1639\"\u003eInstallation of \u003cstrong data-end=\"1676\" data-start=\"1655\"\u003eOMPF O-rings only\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1729\" data-start=\"1679\"\u003e\n\u003cp data-end=\"1729\" data-start=\"1681\"\u003eLubrication using \u003cstrong data-end=\"1727\" data-start=\"1699\"\u003eChristo-Lube exclusively\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1783\" data-start=\"1730\"\u003e\n\u003cp data-end=\"1783\" data-start=\"1732\"\u003ePrecision tuning of cracking pressure and airflow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1832\" data-start=\"1784\"\u003e\n\u003cp data-end=\"1832\" data-start=\"1786\"\u003eFunctional and breathing performance testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1844\" data-start=\"1821\"\u003eWhat's Not Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eService Kits from manufacturer\u003c\/li\u003e\n\u003cli\u003eO-rings that may be needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"1857\" data-start=\"1834\"\u003eService Standards\u003c\/h3\u003e\n\u003cul data-end=\"1999\" data-start=\"1858\"\u003e\n\u003cli data-end=\"1896\" data-start=\"1858\"\u003e\n\u003cp data-end=\"1896\" data-start=\"1860\"\u003eNo aftermarket or substitute parts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1920\" data-start=\"1897\"\u003e\n\u003cp data-end=\"1920\" data-start=\"1899\"\u003eNo mixed lubricants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1944\" data-start=\"1921\"\u003e\n\u003cp data-end=\"1944\" data-start=\"1923\"\u003eNo partial rebuilds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1999\" data-start=\"1945\"\u003e\n\u003cp data-end=\"1999\" data-start=\"1947\"\u003eWork performed in a controlled service environment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2004\" data-start=\"2001\"\u003e\n\u003ch2 data-end=\"2019\" data-start=\"2006\"\u003eWarranty\u003c\/h2\u003e\n\u003cp data-end=\"2264\" data-start=\"2020\"\u003eAll \u003cstrong data-end=\"2095\" data-start=\"2024\"\u003e2nd Stage Full-Service work is backed by a 1-year warranty on labor\u003c\/strong\u003e.\u003cbr data-end=\"2099\" data-start=\"2096\"\u003eThis warranty covers workmanship-related issues under normal use conditions.\u003cbr data-end=\"2178\" data-start=\"2175\"\u003eWear items, misuse, contamination, impact damage, or improper storage are not covered.\u003c\/p\u003e\n\u003chr data-end=\"2269\" data-start=\"2266\"\u003e\n\u003ch2 data-end=\"2302\" data-start=\"2271\"\u003eWhy Choose \u003ca href=\"https:\/\/www.scubarepair.com\" title=\"scubarepair.com\"\u003eScubaRepair.com\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003cul data-end=\"2586\" data-start=\"2303\"\u003e\n\u003cli data-end=\"2362\" data-start=\"2303\"\u003e\n\u003cp data-end=\"2362\" data-start=\"2305\"\u003eCertified and experienced regulator service technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2418\" data-start=\"2363\"\u003e\n\u003cp data-end=\"2418\" data-start=\"2365\"\u003eStrict adherence to manufacturer service procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2472\" data-start=\"2419\"\u003e\n\u003cp data-end=\"2472\" data-start=\"2421\"\u003eOxygen-compatible materials and service practices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2522\" data-start=\"2473\"\u003e\n\u003cp data-end=\"2522\" data-start=\"2475\"\u003eProfessional documentation and accountability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2586\" data-start=\"2523\"\u003e\n\u003cp data-end=\"2586\" data-start=\"2525\"\u003eTrusted by recreational, technical, and professional divers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2591\" data-start=\"2588\"\u003e\n\u003ch2 data-end=\"2613\" data-start=\"2593\"\u003eImportant Notes\u003c\/h2\u003e\n\u003cul data-end=\"2866\" data-start=\"2614\"\u003e\n\u003cli data-end=\"2728\" data-start=\"2614\"\u003e\n\u003cp data-end=\"2728\" data-start=\"2616\"\u003eReplacement of damaged housings, levers, or hard components not included in OEM kits may incur additional cost\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2804\" data-start=\"2729\"\u003e\n\u003cp data-end=\"2804\" data-start=\"2731\"\u003eFirst stage service is \u003cstrong data-end=\"2770\" data-start=\"2754\"\u003enot included\u003c\/strong\u003e and must be selected separately\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2866\" data-start=\"2805\"\u003e\n\u003cp data-end=\"2866\" data-start=\"2807\"\u003eRegulator must be a current, manufacturer-supported model\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2871\" data-start=\"2868\"\u003e\n\u003ch2 data-end=\"2893\" data-start=\"2873\"\u003eRecommended For\u003c\/h2\u003e\n\u003cul data-end=\"3041\" data-start=\"2894\"\u003e\n\u003cli data-end=\"2939\" data-start=\"2894\"\u003e\n\u003cp data-end=\"2939\" data-start=\"2896\"\u003eAnnual or scheduled regulator maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2977\" data-start=\"2940\"\u003e\n\u003cp data-end=\"2977\" data-start=\"2942\"\u003ePrimary and octopus second stages\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3041\" data-start=\"2978\"\u003e\n\u003cp data-end=\"3041\" data-start=\"2980\"\u003eRecreational, technical, and professional diving regulators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3046\" data-start=\"3043\"\u003e\n\u003ch2 data-end=\"3068\" data-start=\"3048\"\u003eTurnaround Time\u003c\/h2\u003e\n\u003cp data-end=\"3160\" data-start=\"3069\"\u003eTypical turnaround is \u003cstrong data-end=\"3113\" data-start=\"3091\"\u003e5–10 business days\u003c\/strong\u003e, depending on parts availability and workload.\u003c\/p\u003e\n\u003chr data-end=\"3165\" data-start=\"3162\"\u003e\n\u003ch2 data-end=\"3182\" data-start=\"3167\"\u003eDisclaimer\u003c\/h2\u003e\n\u003cp data-end=\"3416\" data-start=\"3183\"\u003e\u003ca href=\"https:\/\/www.scubarepair.com\" title=\"scubarepair.com\"\u003eScubaRepair.com\u003c\/a\u003e services regulators in accordance with manufacturer specifications. Unsupported, obsolete, or non-serviceable models may be declined. Warranty applies to service labor only and does not extend manufacturer warranties.\u003c\/p\u003e","brand":"scubarepair.com","offers":[{"title":"Default Title","offer_id":50123711840613,"sku":null,"price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0869\/6502\/7173\/files\/2nd_Stage_Regulator.jpg?v=1767672966","url":"https:\/\/scubarepair.com\/products\/regulator-2nd-stage-full-service-complete-rebuild","provider":"ScubaRepair.com","version":"1.0","type":"link"}